Please see Annex A for the application pressures and other information.
Type of pipe | Type of damage | Nominal size from – to | Application pressure | |
Stoneware, asbestos cement, PVC, and cement pipes | Fragmentation and length-wise cracks | DN 100 / 4” | approx. 6.0–6.5 bar / 87.02–94.27 psi | |
DN 150 / 6” | approx. 4.5–5.0 bar / 65.27–72.52 psi | |||
DN 200 / 8” | approx. 3.5–4.0 bar / 50.76–58.02 psi | |||
DN 250–800 / 10”–32” | approx. 3.0–3.5 bar / 43.51–50.76 psi | |||
Transverse cracks, leaking fittings | DN 100 / 4” | approx. 6.0–6.5 bar / 87.02–94.27 psi | ||
DN 150 / 6” | approx. 4.5–5.0 bar / 65.27–72.52 psi | |||
DN 200 / 8” | approx. 3.5–4.5 bar / 50.76–65.27 psi | |||
DN 250–800 / 10”–32” | approx. 3.5–4.0 bar / 50.76–58.02 psi | |||
Reinforced concrete, fiberglass (PE, PP), and cast pipes | All types of damage | DN 100 / 4” | approx. 6.0–6.5 bar / 87.02–94.27 psi | |
DN 150 / 6” | approx. 4.5–5.0 bar / 65.27–72.52 psi | |||
DN 200–800 / 8”–32” | approx. 3.5–4.0 bar / 50.76–58.02 psi |